Testing and Laboratory
At our laboratory in İzmir, we carry out gas appliance, electrical safety, electrical equipment of machines and electromagnetic compatibility testing, and report results together with measurement uncertainty.

Our testing areas
Gas appliances
Combustion, safety, efficiency and operational testing of gas appliances according to the relevant product standards.
- Combustion, safety and operational testing
- EN 203 series commercial catering appliances
- Efficiency testing of hot-water boilers
Electrical safety
IEC/EN 60335 series testing of household and similar electrical appliances.
- Access to live parts, leakage current, earthing
- Heating, electric strength, moisture resistance
- Abnormal operation, ball pressure, glow wire
Electrical equipment of machines
Verification of the electrical equipment of machines according to EN 60204-1.
- Verification according to EN 60204-1
- Used in machinery certification processes
EMC
Assessment of the electromagnetic compatibility of electrical and electronic equipment according to the relevant standards.
- Electromagnetic emissions
- Electromagnetic immunity
- Assessment according to the relevant standards
Sample receipt, return and disposal
Test items are delivered by you; our laboratory does not carry out sampling within the scope of accreditation. Each sample received is checked for consistency with the request, sufficient quantity and size, transport damage, required accessories and documents (user manual, circuit diagram, gas adjustment information) and whether it can be tested safely.
- A sample unsuitable for testing is rejected with a stated reason.
- A sample with deviations is conditionally accepted at your request; the deviation is stated in the report.
- The relevant test is not started until missing documents or accessories have been provided.
- Your preference for return or disposal after testing is recorded at application; your consent for destructive tests is obtained in the contract.
Report and decision rule
Our reports include the method and standard applied, the results with their units, the measurement uncertainty where applicable and, where a statement of conformity is to be made, the decision rule applied. Each report is reviewed and approved by an authorised person other than the staff member who performed the test.
The decision rule is explained to you before the contract. Where the standard or legislation does not specify a rule and no other agreement exists, simple acceptance applies. Details: Decision rule and measurement uncertainty.
Reports may be issued in Turkish, English or bilingual form; they are delivered electronically (PDF), by hand or by courier.
On-site testing
For products that cannot be transported, testing can be carried out at your facility. Feasibility is assessed first: applicability of the method on site, environmental conditions, equipment, energy and infrastructure, safety and the condition of the sample. If the conditions cannot be met, on-site testing is not carried out and you are informed of the reason. The on-site test report states the location, environmental conditions and any deviations.